WEBVTT

NOTE Machine transcript of the film's sound; not yet checked.

1
00:00:43.750 --> 00:00:44.810
Our sun, the

2
00:00:51.630 --> 00:00:55.390
original H-bomb, the original source of
nuclear fusion.

3
00:00:56.470 --> 00:01:02.420
The origin of all energy on Earth,
billions of years the

4
00:01:02.420 --> 00:01:03.720
only source of heat.

5
00:01:03.900 --> 00:01:07.660
It fostered all life, it nourished all
growth.

6
00:01:09.740 --> 00:01:14.580
Hotter than white hot, fusing
infinitesimal atoms at millions of
degrees.

7
00:01:14.980 --> 00:01:20.480
Its nuclear explosions thrust searing
tentacles 300,000 miles

8
00:01:20.480 --> 00:01:22.940
long into the cold wastes of space.

9
00:01:23.640 --> 00:01:26.900
Little wonder that early man made it his
god.

10
00:01:28.640 --> 00:01:31.140
If there ever were a total eclipse,

11
00:01:31.500 --> 00:01:34.960
one cutting off the sun's light and its
heat as well,

12
00:01:35.180 --> 00:01:37.660
not for a few moments, but forever,

13
00:01:38.400 --> 00:01:41.120
there would be nothing left living on
earth.

14
00:01:42.180 --> 00:01:45.140
But we are spared this frozen desolation,

15
00:01:45.180 --> 00:01:47.340
this eternal barren waste,

16
00:01:47.900 --> 00:01:49.380
for we have heat,

17
00:01:50.080 --> 00:01:52.340
man's most important single resource.

18
00:01:54.160 --> 00:01:59.160
History waited until man learned he could
make fire, could control heat.

19
00:01:59.380 --> 00:02:04.640
And today's world is only possible because
of heat's scientific application to

20
00:02:04.640 --> 00:02:06.740
practically every industrial process.

21
00:02:07.340 --> 00:02:10.540
But what is heat? It is energy.

22
00:02:10.760 --> 00:02:14.100
It can be turned into many other forms of
energy.

23
00:02:14.540 --> 00:02:18.560
It drives steam turbines to provide
mechanical energy.

24
00:02:24.560 --> 00:02:29.340
converted into chemical energy it
literally can move mountains

25
00:02:29.340 --> 00:02:34.980
as electrical energy it lights

26
00:02:34.980 --> 00:02:39.560
our homes powers our commerce our industry
to

27
00:02:41.480 --> 00:02:44.560
control valuable heat through insulation
we

28
00:02:44.560 --> 00:02:50.300
must begin by studying the ways it can
escape the three methods of heat transfer

29
00:02:50.300 --> 00:02:52.140
first by

30
00:02:52.140 --> 00:02:57.300
radiation. Radiant heat, part of the
spectrum of electromagnetic energy,

31
00:02:57.620 --> 00:02:59.180
travels as a wave.

32
00:02:59.620 --> 00:03:05.500
Like light, it can move through a vacuum.
Like light, it travels in a

33
00:03:05.500 --> 00:03:06.500
straight line

34
00:03:06.460 --> 00:03:11.840
at 186,000 miles a second. Put an
obstruction in its way,

35
00:03:12.000 --> 00:03:14.560
and a hot light cannot melt ice

36
00:03:14.560 --> 00:03:18.600
that it doesn't hit. Only the exposed
surface melts.

37
00:03:18.840 --> 00:03:20.620
The part in shadow is

38
00:03:20.620 --> 00:03:22.100
virtually unaffected.

39
00:03:27.360 --> 00:03:31.480
Secondly, heat is transferred by
conduction through solid

40
00:03:31.480 --> 00:03:36.040
materials. Allow steam to pass inside a
metal pipe.

41
00:03:36.400 --> 00:03:38.320
The heat travels quickly

42
00:03:38.320 --> 00:03:42.000
through the metal to the outside. That

43
00:03:45.330 --> 00:03:47.550
heat conduction occurs at different

44
00:03:47.550 --> 00:03:52.170
rates of speed through different materials
is readily apparent in this

45
00:03:52.170 --> 00:03:58.370
demonstration. Identical sized bars of
different metals are heated at one end

46
00:03:58.370 --> 00:04:03.270
by the same heat source. The difference in
time it takes their wax coating to

47
00:04:03.270 --> 00:04:06.750
melt illustrates the wide variation in
conduction.

48
00:04:07.210 --> 00:04:11.850
We can use shadowgraphs to

49
00:04:11.850 --> 00:04:16.810
illustrate the third method of heat
transfer, convection, or the movement of

50
00:04:16.810 --> 00:04:19.270
air from one temperature region to
another.

51
00:04:20.330 --> 00:04:23.070
We can feel the intense heat waves well

52
00:04:23.070 --> 00:04:26.270
above any visible flame, just as we can

53
00:04:26.270 --> 00:04:28.550
feel heat rising from a radiator.

54
00:04:31.850 --> 00:04:34.890
By using a powerful light source to
silhouette

55
00:04:34.890 --> 00:04:38.870
that heat onto a screen, we can see and
study

56
00:04:38.870 --> 00:04:41.090
this rising torrent of hot air.

57
00:04:41.490 --> 00:04:46.720
Cold air in this shadowgraph of a piece of
ice

58
00:04:46.720 --> 00:04:50.720
spills downward, being heavier than the
air about it.

59
00:04:53.680 --> 00:04:55.680
The circulation set up by

60
00:04:55.680 --> 00:05:01.000
these movements of heat causing upward
currents and cold causing downward ones

61
00:05:01.000 --> 00:05:04.660
can be seen even in a so-called dead
airspace.

62
00:05:05.160 --> 00:05:07.360
One face of this box is kept

63
00:05:07.360 --> 00:05:13.180
heated, the other kept cold. Air rises
along the hot surface, crosses

64
00:05:13.180 --> 00:05:14.180
to the

65
00:05:13.640 --> 00:05:16.740
cold side where it is chilled and falls.

66
00:05:17.280 --> 00:05:20.320
Every round trip of this circulating air
means

67
00:05:20.320 --> 00:05:24.700
a loss of heat. It is insulation's job to
prevent such loss.

68
00:05:25.120 --> 00:05:31.310
By using a pipe and valve setup in

69
00:05:31.310 --> 00:05:36.430
still another shadowgraph, we can see a
dramatic example of heat lost by
convection.

70
00:05:39.830 --> 00:05:40.830
The shadow

71
00:05:40.790 --> 00:05:46.430
graph will not show the additional heat
lost by radiation, which may be even
greater.

72
00:05:48.370 --> 00:05:53.870
Insulating both sections of pipe cuts down
the amount of lost heat, but only by
properly

73
00:05:53.870 --> 00:05:59.170
insulating pipe and valve can heat lost by
radiation, conduction,

74
00:05:59.570 --> 00:06:01.650
and convection be kept

75
00:06:01.650 --> 00:06:02.650
to a minimum.

76
00:06:03.750 --> 00:06:09.870
The proper material and the best thickness
must be determined for each specific
installation.

77
00:06:10.390 --> 00:06:15.810
This is part of the work of the insulation
engineer who realizes that whether
insulation

78
00:06:15.810 --> 00:06:21.470
is used for people's comfort and safety
for fire protection to protect equipment

79
00:06:21.470 --> 00:06:27.190
or for process control it is first and
foremost a way to conserve heat a

80
00:06:27.190 --> 00:06:28.190
way to

81
00:06:28.010 --> 00:06:33.920
save money all man-made heat has a price
on

82
00:06:33.920 --> 00:06:36.860
it it costs money to build the

83
00:06:36.860 --> 00:06:41.400
simplest furnace it costs money to supply
it with fuel

84
00:06:41.400 --> 00:06:44.380
it costs money to

85
00:06:44.380 --> 00:06:50.060
hire the people who keep it running. Thus,
every unit of heat energy

86
00:06:50.060 --> 00:06:51.060
that is released

87
00:06:51.000 --> 00:06:56.790
has a definite dollar value. Now, this
energy reaches

88
00:06:56.790 --> 00:07:00.130
the boiler by radiation and by convection.

89
00:07:01.750 --> 00:07:07.710
It moves through the metal boiler walls by
conduction and through the water in

90
00:07:07.710 --> 00:07:08.710
the boiler

91
00:07:08.050 --> 00:07:13.890
by convection. But the furnace walls are
also conductors of

92
00:07:13.890 --> 00:07:16.050
heat, so there is a loss of

93
00:07:16.050 --> 00:07:21.930
heat by conduction through the furnace
walls and by convection and

94
00:07:21.930 --> 00:07:24.390
radiation outside

95
00:07:24.390 --> 00:07:30.250
the walls. The uninsulated boiler wall
transfers

96
00:07:30.250 --> 00:07:34.010
heat out by conduction as easily as it
transfers

97
00:07:34.010 --> 00:07:38.670
it to the water. So there is further heat
loss by radiation

98
00:07:38.670 --> 00:07:43.230
and convection outside the

99
00:07:43.230 --> 00:07:49.010
boiler. Every unit of heat that is wasted
costs exactly

100
00:07:49.010 --> 00:07:51.630
as much money as a unit of heat that is

101
00:07:51.630 --> 00:07:57.620
used. The mission of Johns-Manville is to
provide materials to

102
00:07:57.620 --> 00:08:00.200
save this heat, thus conserving fuel

103
00:08:00.200 --> 00:08:03.800
and concentrating the available energy on
useful work.

104
00:08:05.880 --> 00:08:09.020
Efficient insulating materials pay a far

105
00:08:09.020 --> 00:08:14.340
greater rate of return than can be
expected from practically any other form
of

106
00:08:14.340 --> 00:08:15.340
plant investment.

107
00:08:15.140 --> 00:08:21.100
But what insulating materials will pay the
greatest return?

108
00:08:22.100 --> 00:08:27.600
The men who have the answer draw on a
century of experience in insulation
problems.

109
00:08:28.080 --> 00:08:31.020
They are Johns-Manville insulation
engineers.

110
00:08:33.050 --> 00:08:36.170
What materials? Well, it depends on the
job.

111
00:08:36.830 --> 00:08:40.670
Obviously, no single insulating material
will do everything best.

112
00:08:41.210 --> 00:08:46.150
Our work then at Johns-Manville is to get
the right balance of properties for each
application.

113
00:08:47.070 --> 00:08:53.150
How thick should an insulation be? Well,
you could put this on a steam line, and
compared

114
00:08:53.150 --> 00:08:59.190
to no insulation at all, you'd save a lot
of money. And then, with this, you'd save

115
00:08:59.190 --> 00:09:04.310
additional heat, but the insulation would
cost more. And if somebody insisted, well,

116
00:09:04.350 --> 00:09:08.850
we could insulate way out to here, but
that would cost a lot more, much more than
could

117
00:09:08.850 --> 00:09:13.630
be saved in heat costs. So our job is to
provide insulation with the best balance

118
00:09:13.630 --> 00:09:14.630
of properties

119
00:09:14.150 --> 00:09:16.670
and to calculate the most economic
thickness.

120
00:09:20.130 --> 00:09:22.390
Many factors enter into our calculations.

121
00:09:23.130 --> 00:09:25.850
Operating temperature, hours of operation,

122
00:09:26.170 --> 00:09:30.070
type of installation, cost of heat
production, and so forth.

123
00:09:30.310 --> 00:09:32.710
But they can all be boiled down to these
two.

124
00:09:34.290 --> 00:09:36.510
Annual cost of insulation in place.

125
00:09:37.970 --> 00:09:40.430
Annual cost of remaining heat loss.

126
00:09:41.570 --> 00:09:44.810
Now the sum of these two gives us a basis
for determining

127
00:09:44.810 --> 00:09:49.290
the economic thickness of insulation for
any application.

128
00:09:50.230 --> 00:09:52.190
The annual cost of the insulation

129
00:09:52.190 --> 00:09:55.510
is based on its installed cost and the
rate of amortization.

130
00:10:01.460 --> 00:10:03.000
Now let's assume that on a

131
00:10:03.000 --> 00:10:08.900
steam line the annual insulation cost in
place per foot comes to 12

132
00:10:08.900 --> 00:10:10.540
cents for one inch thick

133
00:10:10.540 --> 00:10:15.880
insulation. The annual heat loss through
this one inch thickness costs a dollar and

134
00:10:15.880 --> 00:10:16.960
51 cents.

135
00:10:16.960 --> 00:10:22.140
The total annual cost then is $1.63 per
foot.

136
00:10:22.720 --> 00:10:25.160
Two inches of insulation naturally

137
00:10:25.160 --> 00:10:30.920
is going to cost more, 24 cents in this
case, but more heat is saved, which

138
00:10:30.920 --> 00:10:31.920
brings the cost

139
00:10:31.640 --> 00:10:37.200
down to 95 cents. Annual total, $1.19.

140
00:10:38.520 --> 00:10:41.840
For three inches of insulation, the cost
goes

141
00:10:41.840 --> 00:10:47.200
up to 37 cents, but the cost of lost heat
drops to 74 cents.

142
00:10:47.740 --> 00:10:50.180
Total annual cost, one

143
00:10:50.180 --> 00:10:55.900
dollar and eleven cents. Four inches of
insulation costs 53 cents.

144
00:10:56.200 --> 00:10:57.260
The cost of

145
00:10:57.260 --> 00:11:03.060
the lost heat has dropped to 64 cents.
However, the additional heat

146
00:11:03.060 --> 00:11:04.060
saved is no

147
00:11:03.960 --> 00:11:08.700
longer enough to justify the added
thickness. The total annual cost, instead

148
00:11:08.700 --> 00:11:13.920
of continuing to fall, has now come back
up to a dollar and 17 cents.

149
00:11:14.560 --> 00:11:19.620
And if we put on greater thicknesses, the
total cost would continue to increase.

150
00:11:20.040 --> 00:11:26.260
So back here, at three inches, we have the
lowest annual cost or economic thickness
for

151
00:11:26.260 --> 00:11:27.260
this job.

152
00:11:35.030 --> 00:11:37.050
Actually, we're a little ahead of
ourselves.

153
00:11:37.570 --> 00:11:39.830
You may ask, three inches of what?

154
00:11:40.410 --> 00:11:44.210
This or this or something else?

155
00:11:44.710 --> 00:11:48.750
Well, one of the first questions is, how
long does it have to last?

156
00:11:49.390 --> 00:11:53.270
Well, that may be measured in decades in
some instances and for much shorter

157
00:11:53.270 --> 00:11:54.270
periods in others.

158
00:11:54.910 --> 00:11:59.490
How long is it going to be under
temperature? Part-time or constantly?

159
00:12:00.170 --> 00:12:02.790
How much physical abuse is it likely to
get?

160
00:12:03.810 --> 00:12:09.450
Now, for example, the pipe insulation in
this oil refinery is going to have to take
it.

161
00:12:09.450 --> 00:12:15.090
Men will lean ladders against it, use it
for catwalks, and that calls for strength

162
00:12:15.090 --> 00:12:19.630
and toughness besides insulating
properties. Lines operating in the same

163
00:12:19.630 --> 00:12:23.750
temperature range but which are protected
inside the walls of a building

164
00:12:23.750 --> 00:12:27.110
for example can be insulated with a
material of less strength.

165
00:12:27.870 --> 00:12:28.870
Perhaps the

166
00:12:28.690 --> 00:12:33.050
insulation will be out in all kinds of
weather. A lot of equipment is nowadays

167
00:12:33.050 --> 00:12:36.570
equipment that used to be housed in
expensive plant buildings.

168
00:12:37.210 --> 00:12:38.390
This means we

169
00:12:38.390 --> 00:12:42.870
need still more qualities in our
insulating material, because the
insulation and

170
00:12:42.870 --> 00:12:43.870
the weatherproofing

171
00:12:43.710 --> 00:12:47.790
over it provide the only weather
protection such valuable equipment is ever
going

172
00:12:47.790 --> 00:12:48.790
to get.

173
00:12:49.990 --> 00:12:55.090
They used to tell us that all we needed
for an ideal insulation was a substance
meeting

174
00:12:55.580 --> 00:13:01.430
these specifications, strength infinite,
weight zero,

175
00:13:01.730 --> 00:13:06.670
cost in place zero, life forever,
conductivity

176
00:13:06.670 --> 00:13:11.990
zero well it's a nice idea but obviously
practical

177
00:13:11.990 --> 00:13:14.050
insulations only approach these

178
00:13:14.050 --> 00:13:19.450
specifications some more closely on one
property and others on different
properties

179
00:13:19.450 --> 00:13:20.730
and insulation

180
00:13:20.730 --> 00:13:26.410
can be made very strong or very light or
very economical very

181
00:13:26.410 --> 00:13:28.670
durable or a very low conductivity

182
00:13:28.670 --> 00:13:33.770
and since different insulation
requirements call for these properties in
different combinations

183
00:13:33.770 --> 00:13:39.310
many raw materials are used, each one
adding its own strongest points

184
00:13:39.310 --> 00:13:41.990
to the Johns-Manville family of insulating
products.

185
00:13:42.790 --> 00:13:45.430
To meet the needs of high-temperature
insulation,

186
00:13:45.830 --> 00:13:49.270
we reach millions of years back in the
geological history.

187
00:13:50.550 --> 00:13:54.170
These white hills of silica are actually
the graveyard

188
00:13:54.170 --> 00:13:57.410
of billions of microscopic organisms
called diatoms

189
00:13:57.410 --> 00:14:00.410
that lived in the ocean that once covered
California.

190
00:14:01.570 --> 00:14:07.570
This diatomaceous silica not only provides
low conductivity, but retains its physical

191
00:14:07.570 --> 00:14:12.070
and chemical stability at temperatures up
to 2,500 degrees Fahrenheit.

192
00:14:14.150 --> 00:14:16.470
Limestone too is an important raw
material.

193
00:14:17.290 --> 00:14:21.610
Combined through a heat process with
diatomaceous silica, it is used to make

194
00:14:21.610 --> 00:14:22.610
calcium silicate

195
00:14:22.590 --> 00:14:28.430
insulation, material of great permanence
and strength, light in weight, low

196
00:14:28.430 --> 00:14:29.430
in thermal

197
00:14:29.010 --> 00:14:33.870
conductivity stable when wet and having
excellent insulating qualities

198
00:14:33.870 --> 00:14:37.330
dolomite rock is the starting

199
00:14:37.330 --> 00:14:43.150
raw material for 85% magnesia insulation a
product less strong than calcium

200
00:14:43.150 --> 00:14:44.990
silicate but also having

201
00:14:44.990 --> 00:14:50.590
low thermal conductivity magnesia has been
the most widely used insulation

202
00:14:50.590 --> 00:14:51.590
for industrial

203
00:14:51.470 --> 00:14:57.340
applications to 600 degrees from the
world's largest

204
00:14:57.340 --> 00:15:00.620
asbestos mine located in Canada Johns-
Manville

205
00:15:00.620 --> 00:15:05.920
takes the magic mineral called asbestos
soft silky fibers of great

206
00:15:05.920 --> 00:15:08.080
strength inorganic

207
00:15:08.640 --> 00:15:14.640
light fire resistant asbestos is the ideal
reinforcing agent for thermal insulation

208
00:15:17.080 --> 00:15:23.000
for a strong insulation with low first
cost a heat process is used to expand a

209
00:15:23.000 --> 00:15:24.000
volcanic rock

210
00:15:23.760 --> 00:15:28.780
in which molecular water has been trapped
a rock this size is converted into this

211
00:15:28.780 --> 00:15:29.780
large mass of

212
00:15:29.740 --> 00:15:35.520
light cellular insulating material. The
violent

213
00:15:35.520 --> 00:15:37.200
temperatures of a volcano made

214
00:15:37.200 --> 00:15:40.180
by man are needed to manufacture mineral
fiber.

215
00:15:43.990 --> 00:15:45.910
Streams of molten materials are

216
00:15:45.910 --> 00:15:48.950
made into silky strands far finer than
human hair.

217
00:15:50.770 --> 00:15:56.540
One of the oldest natural insulating
materials is clay.

218
00:15:56.940 --> 00:15:58.600
In special clays are

219
00:15:58.600 --> 00:16:02.260
found the refractory qualities needed for
manufacturing a variety of

220
00:16:02.260 --> 00:16:05.560
insulating fire brick that defy extremely
high temperatures.

221
00:16:06.200 --> 00:16:07.200
It

222
00:16:16.820 --> 00:16:17.820
takes a

223
00:16:17.280 --> 00:16:22.820
wide variety of production techniques and
specially designed modern equipment to
turn

224
00:16:22.820 --> 00:16:26.940
these raw materials into the finished
products used throughout the world.

225
00:16:27.260 --> 00:16:28.580
From the many Johns-Manville

226
00:16:28.580 --> 00:16:33.020
factories come products in many forms.
Pipe insulations,

227
00:16:33.400 --> 00:16:37.200
block insulations, insulating

228
00:16:37.200 --> 00:16:42.620
brick, metal clad insulations, mineral
fiber felts,

229
00:16:42.700 --> 00:16:45.640
refractories, and structural sheet

230
00:16:45.640 --> 00:16:50.380
insulations. In this family of products
are the answers to insulation

231
00:16:50.380 --> 00:16:51.400
problems that

232
00:16:51.400 --> 00:16:56.960
range from hundreds of degrees Fahrenheit
below zero to thousands of degrees above.

233
00:16:59.470 --> 00:17:05.250
Such home appliances as refrigerators,
freezers, water heaters, and ranges can

234
00:17:05.250 --> 00:17:06.250
be made better

235
00:17:06.210 --> 00:17:12.250
to serve better with the remarkable
mineral fiber insulation developed by
Johns-Manville.

236
00:17:13.230 --> 00:17:19.050
At sea, another of the company's
discoveries contributes to the safety and
comfort

237
00:17:19.050 --> 00:17:20.050
of passengers

238
00:17:19.790 --> 00:17:20.790
and crew.

239
00:17:20.970 --> 00:17:26.790
These attractive walls and ceilings are
built of lightweight and fireproof panels.

240
00:17:28.010 --> 00:17:34.650
And the same material, since it combines
structural strength with high temperature
insulating

241
00:17:34.650 --> 00:17:40.510
qualities, is used to build ovens, dryers,
and similar high

242
00:17:40.510 --> 00:17:41.510
heat equipment.

243
00:17:43.210 --> 00:17:48.230
Johns-Manville's leadership in the science
of insulation stems not only from its

244
00:17:48.230 --> 00:17:52.430
products, but also from its organization
of experienced contractors.

245
00:17:52.950 --> 00:17:54.050
Chosen for

246
00:17:54.050 --> 00:17:59.190
their integrity and skill, they know the
right application methods for every kind

247
00:17:59.190 --> 00:18:04.960
of service. In plumbing and heating
systems, they apply pipe

248
00:18:04.960 --> 00:18:05.960
insulations to

249
00:18:05.880 --> 00:18:08.680
cut heat loss or to reduce condensation.

250
00:18:09.960 --> 00:18:12.680
With duct insulation, they add efficiency

251
00:18:12.680 --> 00:18:15.700
to air conditioning systems by holding
down

252
00:18:15.700 --> 00:18:18.560
the air temperature on its way to room
outlets.

253
00:18:19.000 --> 00:18:23.340
In this cold storage room, inorganic,

254
00:18:23.340 --> 00:18:26.260
moisture-resistant insulation will help
maintain

255
00:18:26.260 --> 00:18:28.660
the extreme temperature needed to preserve

256
00:18:28.660 --> 00:18:30.480
perishable food and beverages.

257
00:18:32.460 --> 00:18:35.240
The petroleum and petrochemical industries

258
00:18:35.240 --> 00:18:39.920
depend on many types of thermal insulation
for process control, for

259
00:18:39.920 --> 00:18:45.500
safety, and for economic operation. In the
power industry,

260
00:18:45.860 --> 00:18:47.260
Johns-Manville products

261
00:18:47.260 --> 00:18:51.100
are part of the engineering triumphs that
have made the generating of

262
00:18:51.100 --> 00:18:56.790
electricity more and more economical. This
family of

263
00:18:56.790 --> 00:18:58.310
insulating materials also

264
00:18:58.310 --> 00:19:03.570
plays a part in conserving atomic fuels in
the nuclear reactors of power plants.

265
00:19:03.570 --> 00:19:09.120
In the steel industry, too, where
temperatures climb past 2,000

266
00:19:09.120 --> 00:19:11.780
degrees, Johns-Manville products

267
00:19:11.780 --> 00:19:15.240
are at work, saving fuel and improving
operation.

268
00:19:16.180 --> 00:19:21.440
In the high-temperature world of modern
industry, insulation is an important

269
00:19:21.440 --> 00:19:22.440
capital investment

270
00:19:22.960 --> 00:19:26.180
demanding exacting design and proper
application.

271
00:19:27.580 --> 00:19:32.320
The Johns-Manville Research Center is
dedicated to finding ways of making

272
00:19:32.320 --> 00:19:33.500
industry's insulation

273
00:19:33.500 --> 00:19:36.660
investment yield the greatest possible
return

274
00:19:36.660 --> 00:19:41.840
here researchers are at work on

275
00:19:41.840 --> 00:19:46.900
basic studies in the economics of the
control of heat here

276
00:19:48.180 --> 00:19:49.200
is not only the

277
00:19:49.200 --> 00:19:53.800
thorough testing and appraisal of newly
developed materials but a constant

278
00:19:53.800 --> 00:19:59.780
quality control of existing products as
well in the thermal conductivity

279
00:19:59.780 --> 00:20:04.840
laboratory, guarded hot plate apparatus is
used to test block insulations.

280
00:20:10.660 --> 00:20:15.620
Electrically heated pipes in a room with
constant temperature are used in testing

281
00:20:15.620 --> 00:20:20.940
pipe insulations. The heat loss through
all test samples is measured by

282
00:20:20.940 --> 00:20:24.560
computing the electrical energy needed to
make up that loss.

283
00:20:25.240 --> 00:20:26.520
To assure the

284
00:20:26.520 --> 00:20:31.140
highest accuracy in these measurements,
every test unit is fed from one master

285
00:20:31.140 --> 00:20:35.140
a switchboard designed to deliver a
constant output of power.

286
00:20:35.860 --> 00:20:38.340
As a check, readings are taken

287
00:20:38.340 --> 00:20:44.300
every hour while the tests are underway.
With such precision equipment

288
00:20:44.300 --> 00:20:45.760
as this, the research

289
00:20:45.760 --> 00:20:49.860
engineers can measure the finest
variations of insulation conductivity.

290
00:20:50.520 --> 00:20:55.000
There are many other

291
00:20:55.000 --> 00:21:00.360
properties to be tested. In the spalling
test, panels of insulating fire brick

292
00:21:00.360 --> 00:21:01.360
under intense

293
00:21:01.180 --> 00:21:04.920
heat are subjected to cycles of cold water
sprays.

294
00:21:06.100 --> 00:21:07.740
This is a means of

295
00:21:07.740 --> 00:21:10.080
determining their resistance to thermal
shock.

296
00:21:13.100 --> 00:21:15.300
Insulating qualities are not the

297
00:21:15.300 --> 00:21:20.500
only ones tested. For certain materials
structural strength and other physical

298
00:21:20.500 --> 00:21:24.440
qualities are every bit as important as
insulating efficiency.

299
00:21:25.180 --> 00:21:26.320
Here a panel

300
00:21:26.320 --> 00:21:31.860
undergoes a rupture test and when a new
product finally

301
00:21:31.860 --> 00:21:32.960
emerges from its

302
00:21:32.960 --> 00:21:38.420
experimental stage, it too must undergo
the most rigorous tests science can

303
00:21:38.420 --> 00:21:42.040
devise before it is made available for
practical use.

304
00:21:45.960 --> 00:21:47.360
Anticipating future needs,

305
00:21:47.660 --> 00:21:53.460
the Research Center is engaged in many
projects. One such project resulted in a

306
00:21:53.460 --> 00:21:58.980
new concept of basic insulation design of
direct interest to the insulation

307
00:21:58.980 --> 00:22:04.770
engineer in the field. What he's talking

308
00:22:04.770 --> 00:22:06.990
about is the mean free path theory of

309
00:22:06.990 --> 00:22:09.770
gas conduction that is applied to
insulation research

310
00:22:09.770 --> 00:22:10.950
at Johns-Manville.

311
00:22:11.690 --> 00:22:14.190
Now this theory provides a scientific way

312
00:22:14.190 --> 00:22:16.610
of knowing how an insulation is going to
perform

313
00:22:17.070 --> 00:22:18.590
while it's still on the drawing board.

314
00:22:19.070 --> 00:22:20.630
Let me give you just one example.

315
00:22:23.720 --> 00:22:27.860
In missile design, space and weight are at
a great premium.

316
00:22:28.060 --> 00:22:30.660
Yet some space and weight must be allowed

317
00:22:30.660 --> 00:22:33.120
for insulation needed to protect sensitive
instruments,

318
00:22:33.340 --> 00:22:36.960
controls, and structures subject to very
intense heat.

319
00:22:36.960 --> 00:22:42.840
Now, working within these space and weight
restrictions, Johns-Manville, using this
mean

320
00:22:42.840 --> 00:22:48.000
free path theory, has designed and created
a material that closely approaches

321
00:22:48.000 --> 00:22:49.720
our so-called

322
00:22:49.720 --> 00:22:50.860
ideal insulation.

323
00:22:51.320 --> 00:22:57.120
Its name is Min-K, which is short for
minimum conductivity.

324
00:22:57.500 --> 00:23:00.740
And minimum is, well, it's almost an
understatement.

325
00:23:00.740 --> 00:23:06.620
Min-K has been designed to have an even
lower conductivity than the theoretical

326
00:23:06.620 --> 00:23:08.280
minimum of still air.

327
00:23:08.860 --> 00:23:14.800
A one inch thickness of Min-K is more
efficient than several times that amount
of

328
00:23:14.800 --> 00:23:15.800
conventional insulation.

329
00:23:16.100 --> 00:23:22.110
Made to help man in his conquest of space.

330
00:23:22.850 --> 00:23:27.330
Who can say what doors this revolutionary
material may open to more efficient

331
00:23:27.330 --> 00:23:28.850
industrial insulations?

332
00:23:39.320 --> 00:23:45.240
Not only in man's conquest of outer space
that control of extreme temperatures is
important,

333
00:23:45.560 --> 00:23:50.200
the jet engines of supersonic planes also
develop intense heat.

334
00:23:50.440 --> 00:23:54.940
To shield them, Johns-Manville has
designed a unique type of insulation.

335
00:23:55.360 --> 00:24:00.880
This insulation is custom fabricated of
high temperature refractory felts

336
00:24:00.880 --> 00:24:02.160
encased in stainless

337
00:24:02.160 --> 00:24:07.820
steel, titanium, and other high heat
resistant metal foils.

338
00:24:07.820 --> 00:24:13.800
All progress stems from new products and
new

339
00:24:13.800 --> 00:24:17.560
processes and in turn all these products
and

340
00:24:17.560 --> 00:24:23.400
processes depend on heat. Heat and
conservation of the fuels which make

341
00:24:23.400 --> 00:24:25.220
it becomes yearly more

342
00:24:25.220 --> 00:24:30.840
vital to us and to our civilization. New
fuels,

343
00:24:31.200 --> 00:24:34.720
new needs of industry push operating
temperatures

344
00:24:34.720 --> 00:24:40.540
ever upward. Scientists now talk in the
millions of degrees.

345
00:24:41.460 --> 00:24:42.460
Temperatures in the

346
00:24:42.460 --> 00:24:46.480
tens of millions can be anticipated in the
field of nuclear fusion.

347
00:24:47.980 --> 00:24:52.720
Johns-Manville's work in insulation
research is aimed today at these

348
00:24:52.720 --> 00:24:58.060
foreseeable goals of tomorrow. To help
make useful to man heat energy

349
00:24:58.060 --> 00:25:03.540
originating at temperatures far greater
than the heat of the raging inferno that

350
00:25:03.540 --> 00:25:04.600
That is our song.