The study

In plain English

This short communication, by an author at James Hardie & Co. in Australia, described a small personal sampler for measuring a worker's asbestos dust exposure over a full shift. The author explained that the Australian hygiene standard for chrysotile and amosite was based on an eight-hour time-weighted average. The unit used a modified aquarium pump with a rechargeable battery, weighed 250 g, and drew air through a filter worn at the collarbone. In a test on one technician with four filter holders, 13 sets of filters were exposed to artificially produced dust clouds. Geometric means were 6.28 and 6.08 fibres/ml at the right and left collarbone positions and 6.16 and 5.92 fibres/ml at the right and left nose positions. The author reported no significant differences due to sampler position. About 700 samples had been collected with 25 pumps in a workforce of some 2000 people. About twenty filters showed no uneven dust deposit at the suggested flow rate, but samples taken above 90 ml/min tended to deposit more dust at the filter centre.

We wrote this plain-English summary from the full article with the help of AI, and a second AI model checked each sentence against the article. It is not the authors' wording; the abstract and the article are their own account.

What the study did and found

  • Design: short communication describing a personal dust sampling device, with a small test of sampler position on one person
  • Who was studied: Device used in surveillance of a workforce of some 2000 people (author's employer, James Hardie & Co., Australia); about 700 samples collected with 25 pumps; position test done on one technician with 13 sets of four filters
  • Exposure: Airborne asbestos dust; the Australian hygiene standard cited covers chrysotile and amosite; recommended flow of 30 ml/min for asbestos dust levels of 2 to 16 fibres/ml, 60 ml/min below 2 fibres/ml
  • Main results:
    • The complete unit measured 100 x 70 x 45 mm and weighed 250 g
    • In the position test (13 sets of four filters on one technician, artificial dust clouds), geometric means were 6.28 and 6.08 fibres/ml at the right and left mid-clavicular positions and 6.16 and 5.92 fibres/ml at the right and left paranasal positions
    • Statistical analysis showed no significant differences in measurements due to sampler position
    • Pre-sampling flow checks gave a flow rate known to within 5%
    • Dust appeared evenly distributed across the filter at the suggested flow rate (about twenty filters checked)
    • The original prototype pump, first used in the field in August 1973, continued to operate satisfactorily after some 500 hours of use
    • 45 of the pumps had been used by government authorities and private industry in Australia
  • The authors' conclusion: The author reported that a small light-weight personal sampler for full-shift asbestos dust measurement had been developed and was in use for workforce surveillance
  • Limitations the authors state:
    • Samples taken at flow rates above 90 ml/min showed a trend toward more dust deposited at the filter centre, so the author suggested counting across a filter diameter
    • Some early pump failures occurred from insufficient battery charging, traced to poor charger connections

Browse more research in The Annals of Occupational Hygiene, or return to medical research.

Cited on this site

How to cite it

Cite the study

J.W. Winters. A simple small light-weight personal dust sampling unit for full shift determination of asbestos dust exposure. The Annals of Occupational Hygiene 1976;19(1):77-80. doi:10.1093/annhyg/19.1.77. PMID: 970848.

Cite our summary

“A simple small light-weight personal dust sampling unit for full shift determination of asbestos dust exposure.” AsbestosClaims.Law Library. https://asbestosclaims.law/library/research/a-simple-small-light-weight-personal-dust-sampling-unit-for-full.

ACL Doc numbers and their short links never change. See how to cite the Library.

Talk with an asbestos lawyer

Start with what you remember, and we'll take it from there.

This page is provided for general informational purposes and does not constitute legal advice. Every asbestos case turns on its own facts, exposure history, diagnosis, deadlines, available evidence, and applicable law. Reviewing this page does not create an attorney-client relationship. For advice about your specific situation, call 833-4-ASBESTOS for a free case review.