No fee unless we recover compensation for your family Text size 833-4-ASBESTOS (833-427-2378) Free Case Review

Clearing and mounting techniques for the evaluation of asbestos fibres by the membrane filter method

Our plain-English summary of Clearing and mounting techniques for the evaluation of asbestos fibres by the membrane filter method, by J.M. Le Guen, S. Galvin (The Annals of Occupational Hygiene, 1981).

You don't need the product names or old records. No fee unless we recover compensation for your family.

Call 833-4-ASBESTOS Request a review

The study

Abstract

This paper describes three clearing and mounting techniques used in the evaluation of fibres by the membrane filter method and puts forward new methods for clearing membrane filters made of mixed esters of cellulose. The paper also sets out criteria for assessing the relative merits of clearing and mounting techniques and shows that, judged by these criteria, one of the new methods offers considerable advantages over the other methods described.

PubMed has no abstract for this study. This is the authors' abstract, copied from the article.

In plain English

This laboratory study compared four ways of preparing membrane filters so that airborne asbestos fibres can be counted under a phase contrast microscope. Two methods were already used in the United Kingdom (triacetin and acetone/triacetin). Two were new (dimethylformamide/Euparal, called DMF/Euparal, and acetone/Euparal). Forty-eight gridded filters sampled chrysotile asbestos clouds in a test chamber and were divided into 12 sets of four. Three operators prepared filters by all four methods and graded the results. Triacetin gave a very granular background and needed considerable refocusing, though it gave the best contrast for chrysotile. DMF/Euparal showed negligible grid distortion and a very clear background. Its filters showed no detectable change over 24 months, while acetone/triacetin filters showed minor fibre movement within the first few weeks. The acetone methods were judged the most hazardous because acetone vapour is flammable. The authors concluded that DMF/Euparal best met their criteria for a versatile method, and that triacetin was adequate when a permanent slide is not needed. The study did not compare fibre counts between methods.

We wrote this plain-English summary from the full article with the help of AI, and a second AI model checked each sentence against the article. It is not the authors' wording; the abstract and the article are their own account.

What the study did and found

  • Design: laboratory comparison of filter clearing and mounting methods
  • Who was studied: 48 gridded membrane filters made of mixed esters of cellulose, divided into 12 sets of four and examined by three operators, over a period of 18 months (UK Health and Safety Executive laboratory)
  • Exposure: Filters were used to sample homogeneous clouds of chrysotile asbestos generated in a test chamber, then cleared by four methods: triacetin, acetone/triacetin, DMF/Euparal and acetone/Euparal
  • Main results:
    • Background clarity: triacetin-treated filters had a very granular background, acetone/triacetin gave varying clarity, and both acetone/Euparal and DMF/Euparal gave very clear backgrounds
    • Contrast: triacetin gave the best contrast for chrysotile fibres. All four techniques gave about the same contrast for amphiboles.
    • Refocusing: only the triacetin method demanded considerable refocusing during a fibre count
    • Filter distortion: DMF/Euparal produced negligible grid distortion
    • Keeping properties: DMF/Euparal filters showed no detectable change over 24 months, while acetone/triacetin filters showed minor fibre movement within the first few weeks
    • Hazard: the acetone vapour methods were considered the most hazardous. For DMF/Euparal, measured breathing-zone DMF concentrations did not exceed a small fraction of the TLV (threshold limit value).
    • Waiting time before analysis: the best results were obtained with DMF/Euparal and acetone/Euparal
  • The authors' conclusion: The authors concluded that, of the methods tested, the new DMF/Euparal method best met their criteria for a versatile method. They considered triacetin clearing adequate when a permanent slide is not required.
  • Limitations the authors state:
    • The authors state that relative fibre counts associated with the different mounting methods were not reported here and would be published independently

Topics

Medical terms in this study, explained in our Lexicon: Membrane Filter Method.

Browse more research in The Annals of Occupational Hygiene, or return to medical research.

Cited on this site

How to cite it

Cite the study

J.M. Le Guen, S. Galvin. Clearing and mounting techniques for the evaluation of asbestos fibres by the membrane filter method. The Annals of Occupational Hygiene 1981;24(3):273-80. doi:10.1093/annhyg/24.3.273. PMID: 7316327.

Cite our summary

“Clearing and mounting techniques for the evaluation of asbestos fibres by the membrane filter method.” AsbestosClaims.Law Library. https://asbestosclaims.law/library/research/clearing-and-mounting-techniques-for-the-evaluation-of-asbestos.

ACL Doc numbers and their short links never change. See how to cite the Library.

Talk with an asbestos lawyer

Start with what you remember, and we'll take it from there.

This page is provided for general informational purposes and does not constitute legal advice. Every asbestos case turns on its own facts, exposure history, diagnosis, deadlines, available evidence, and applicable law. Reviewing this page does not create an attorney-client relationship. For advice about your specific situation, call 833-4-ASBESTOS for a free case review.