Our plain-English summary of Dose estimation for internal organs during boron neutron capture therapy for body-trunk tumors, by Y. Sakurai, H. Tanaka, M. Suzuki, et al (Applied Radiation and Isotopes, 2014).
You don't need the product names or old records. No fee unless we recover compensation for your family.
The study
- Authors: Y. Sakurai, H. Tanaka, M. Suzuki, S. Masunaga, Y. Kinashi, N. Kondo, K. Ono, A. Maruhashi
- Journal: Applied Radiation and Isotopes
- Published: 2014;88:43-5
- Cited by: 3 articles, as counted by NIH iCite
- Read it: PubMed · Publisher
Abstract
Radiation doses during boron neutron capture therapy for body-trunk tumors were estimated for various internal organs, using data from patients treated at Kyoto University Research Reactor Institute. Dose-volume histograms were constructed for tissues of the lung, liver, kidney, pancreas, and bowel. For pleural mesothelioma, the target total dose to the normal lung tissues on the diseased side is 5Gy-Eq in average for the whole lung. It was confirmed that the dose to the liver should be carefully considered in cases of right lung disease.
Copyright © 2014 Elsevier Ltd. All rights reserved.
In plain English
This short technical report from Kyoto University Research Reactor Institute in Japan looked at boron neutron capture therapy (BNCT), a radiation treatment, for tumors in the chest and abdomen, including pleural mesothelioma. It did not study asbestos exposure. By December 2012 the facility had performed 46 such irradiations: 9 for liver tumors, 34 for lung tumors and 3 for other abdominal tumors. The authors used a computer dose-planning system and patients' CT scans to estimate radiation doses to nearby organs. For liver-tumor treatment, assuming a typical irradiation geometry and a boron-10 concentration of 10 ppm, the estimated kidney dose ranged from 1 to 6 Gy-Eq, averaging 3 Gy-Eq. In one patient with lung cancer recurring in the lower left lung, the colon had the highest average dose, 9.1 Gy-Eq. In one patient with right-sided pleural mesothelioma, average doses were 4.9 Gy-Eq to the diseased lung, 1.4 to the healthy lung and 2.9 to the liver. The authors concluded that bowel dose needs careful consideration when treating the lower lung, and liver dose when the right lung is diseased. They noted the kidney doses may be overestimated.
We wrote this plain-English summary from the full article with the help of AI, and a second AI model checked each sentence against the article. It is not the authors' wording; the abstract and the article are their own account.
What the study did and found
- Design: Radiation dose-estimation (treatment-planning) analysis using data from patients treated with BNCT, with example cases. It is not an epidemiological study of asbestos.
- Who was studied: Patients with body-trunk tumors treated at the Heavy Water Neutron Irradiation Facility of the Kyoto University Reactor, Japan. There were 46 irradiations as of December 2012 (9 liver, 34 lung, 3 other abdominal). Detailed dose results are shown for one patient with recurrent lower-left lung cancer and one patient with pleural mesothelioma.
- Exposure: Therapeutic radiation from boron neutron capture therapy using the boron compounds boronophenylalanine (BPA) and/or borocaptate sodium (BSH). Only BPA was used for lung tumors. For pleural mesothelioma, the whole diseased lung was irradiated from four fields. Asbestos exposure was not studied.
- Main results:
- In BNCT for liver tumors, the estimated kidney dose ranged from 1 to 6 Gy-Eq, with an average of 3 Gy-Eq. These estimates assume the typical irradiation geometry and a boron-10 concentration of 10 ppm.
- In liver-tumor BNCT, the estimated right kidney dose was 10 to 50% higher than the liver dose. The left kidney dose was about one-tenth of the right kidney dose.
- In one patient with cancer of the lower left lung, the colon received the highest dose (average 9.1 Gy-Eq, maximum 17.6 Gy-Eq). Other average doses were lung 2.5, kidney 4.8, pancreas 1.8, stomach 3.6 and spinal cord 1.9 Gy-Eq.
- In one patient with pleural mesothelioma of the right lung, average and maximum doses were: diseased lung 4.9 and 9.1 Gy-Eq; healthy lung 1.4 and 4.1 Gy-Eq; liver 2.9 and 9.4 Gy-Eq.
- In the mesothelioma patient, the liver's maximum dose was almost the same as the diseased lung's dose. The healthy lung's average dose was less than one-third of the diseased lung's.
- The authors' conclusion: The authors concluded that bowel dose should be carefully considered when irradiating the lower lung. In mesothelioma of the right lung, the liver dose is higher and is also important.
- Limitations the authors state:
- The kidney doses in liver-tumor BNCT may be overestimated because of high estimates for the biological effectiveness factor and the boron-10 concentration.
- The biological effectiveness factor for the kidney was a tentative assumption and is not precisely known.
- For liver tumors, the embolized regions could not be measured exactly, so the whole liver was used as the target volume.
Topics
Medical terms in this study, explained in our Lexicon: Pleural Mesothelioma.
Related studies
- Geometric dose prediction model for hemithoracic intensity-modulated radiation therapy in mesothelioma patients with two intact lungs — L. Kuo, E.D. Yorke, et al. (2016)
- Tomotherapy PET-guided dose escalation: A dosimetric feasibility study for patients with malignant pleural mesothelioma — A. Maggio, C. Cutaia, et al. (2016)
- Illumination profile characterization of a light device for the dosimetry of intra-pleural photodynamic therapy for mesothelioma — C. Munck, S. Mordon, et al. (2016)
- Real-time light dosimetry for intra-cavity photodynamic therapy: Application for pleural mesothelioma treatment — N. Betrouni, C. Munck, et al. (2017)
- PET-guided dose escalation tomotherapy in malignant pleural mesothelioma — A. Fodor, C. Fiorino, et al. (2011)
- Does selective pleural irradiation of malignant pleural mesothelioma allow radiation dose escalation? : A planning study — A. Botticella, G. Defraene, et al. (2017)
Browse return to medical research.
How to cite it
Cite the study
Y. Sakurai, H. Tanaka, M. Suzuki, S. Masunaga, Y. Kinashi, N. Kondo, et al. Dose estimation for internal organs during boron neutron capture therapy for body-trunk tumors. Applied Radiation and Isotopes 2014;88:43-5. doi:10.1016/j.apradiso.2014.03.005. PMID: 24679832.
Cite our summary
“Dose estimation for internal organs during boron neutron capture therapy for body-trunk tumors.” AsbestosClaims.Law Library. https://asbestosclaims.law/library/research/dose-estimation-for-internal-organs-during-boron-neutron-capture.
ACL Doc numbers and their short links never change. See how to cite the Library.
Talk with an asbestos lawyer
Start with what you remember, and we'll take it from there.
This page is provided for general informational purposes and does not constitute legal advice. Every asbestos case turns on its own facts, exposure history, diagnosis, deadlines, available evidence, and applicable law. Reviewing this page does not create an attorney-client relationship. For advice about your specific situation, call 833-4-ASBESTOS for a free case review.