Company document · Union Carbide documents · July 9, 1976
H. H. Frazier to P. H. Day on Employee Exposure to Asbestos in Plant Stores Building 330 (1976)
Memo reporting area and personal air samples for asbestos fibers taken on June 7 and June 16, 1976 at asbestos rope and gasket storage bins in Plant Stores Building 330, after questions from Plant Stores employees. Counts ranged from 0.0 to 1.0…
-
Company document · Union Carbide documents · January 24, 1973
H. H. Frazier to Fred Williams on Asbestos Sampling Values in the Plant 511 Insulation Fabrication Shop (1973)
Internal correspondence from the Employee Relations Hygiene/Safety department at the Institute Plant, forwarding asbestos fiber counts from 15 personal samples taken in 1972 at the Plant 511 Insulation Fabrication Shop. The tasks sampled involved…
-
Company document · Union Carbide documents · April 6, 1976
H. H. Frazier to J. F. Ballew, Jr. on Airborne Asbestos Fiber Counts During Preparation of Residue Analysis Sample Dishes, Institute Plant (1976)
Memo from H. H. Frazier of Industrial Hygiene to J. F. Ballew, Jr. reporting three fiber-count samplings of employees preparing sample dishes with asbestos fibers in Analytical Laboratory Room 108, with results of 4.9, 47.6 and 7.7 fibers/ml. It…
-
Company document · Union Carbide documents · March 15, 1979
H. H. Frazier to Peter Barna on Use of AMATEX Asbestos Tape in Plant 512 (1979)
Memo from H. H. Frazier to Peter Barna on three brands of insulating tape used at the Institute Plant. It reports that AMATEX tape contained raw asbestos fibers including dust, cites measurements of 0.03 to 1.9 fibers per cc at the Technical Center,…
-
Company document · Union Carbide documents · January 31, 1973
Fred Williams to R. H. Steinberg Forwarding H. A. Frazier's Asbestos Sampling Values for the Insulation Fabrication Shop (1973)
A handwritten memo dated 1/31/1973 from Fred Williams to R. H. Steinberg forwards a summation on asbestos in insulation and asbestos air-sampling results collected by Harold Frazier. It says Williams will present a program for OSHA compliance and…
-
Company document · Union Carbide documents · July 9, 1976
H. H. Frazier to P. H. Day on Employee Exposure to Asbestos in Plant Stores, Building 330 (1976)
Memo reporting area and personal air samples for asbestos taken in June 1976 in Plant Stores Building 330, where asbestos rope and metal-reinforced gaskets were stored and dispensed. It states that the results were within the new TLV of two fibers…
-
Company document · Union Carbide documents · October 14, 1981
H. H. Frazier to R. E. Peele on Monitoring for Asbestos Exposure Potential in the 511 Construction Gasket Shop (1981)
One-page internal Union Carbide memo from Industrial Hygiene at the Institute Plant, West Virginia. It reports that two personal and two area air samples were collected in the 511 Construction Gasket Shop to measure airborne…
-
Company document · Union Carbide documents · July 8, 1976
H. H. Frazier to A. R. Clark on Asbestos Exposure Associated With Automotive Brake Systems, with April 1976 Frazier Memo to J. F. Ballew Jr. on Laboratory Asbestos Fiber Counts (1976)
Two internal Union Carbide Institute Plant memos by H. H. Frazier. The July 8, 1976 memo reports fiber counts taken on a mechanic during three brake service tasks (0.4, 0.2 and 1.9 fibers…
-
Company document · Union Carbide documents · March 15, 1983
H. H. Frazier to R. G. Hull, Jr. on Personal Asbestos Exposure During Acetone Unit Demolition, Complex VI (1983)
Internal Union Carbide memo from Industrial Hygiene at the Institute Plant reporting three airborne asbestos samples taken during insulation demolition at the Acetone Unit. It gives results of 0.2, 0.5 and 0.8 fibers…
-
Company document · Union Carbide documents · March 15, 1983
H. H. Frazier to P. J. Morris on Personal Asbestos Exposure Monitoring of Two Insulator/Painters at Maintenance Complex VIII, Institute Plant (1983)
Internal Union Carbide memo reporting personal air monitoring of two insulator/painters removing protective covering from asbestos-insulated pipe valve at Maintenance Complex VIII on 2/3/83. It reports 15-minute results of 0.8…