- Sent to: Bipin H. Avashia
- Organization: Union Carbide Corporation, Technical Center, South Charleston, WV
- Clear filters
3 results for “Union Carbide Corporation”
-
Company document · Union Carbide documents · July 16, 1982
Manhar A. Patel to J. C. Smith on Dust and MEK Monitoring in the Sandblast Shed, 511 Construction Institute Plant (1982)
Internal Union Carbide letter reporting dust sampling for 'Black Beauty' in the Sandblast Shed and methyl ethyl ketone (MEK) sampling in the Paint Preparation Shed at the 511 Construction Institute Plant, May-June 1982. It says…
-
Company document · Union Carbide documents · July 23, 1987
Industrial Hygiene to H. E. Rucker on Asbestos Exposure Monitoring During Pipe Insulation Removal at the Institute Plant (1987)
Internal Union Carbide memo reporting asbestos air monitoring on insulators who stripped about 195 feet of 3-inch steam line at the Institute Plant tank farm. It states that all personal samples were below the 0…
-
Company document · Union Carbide documents · April 12, 1985
G. W. Phares to B. H. Avashia and Others on Asbestos Monitoring at the Institute Plant SEVIN Unit (1985)
Internal Union Carbide memo reporting asbestos exposure monitoring on April 9, 1985, when two construction insulators stripped about 20 ft. of old insulation from a 6 inch steam line at the SEVIN unit at the Institute…