6 results for “Union Carbide Corporation”
-
Company document · Union Carbide documents · March 15, 1979
H. H. Frazier to Peter Barna on Use of AMATEX Asbestos Tape in Plant 512 (1979)
Memo from H. H. Frazier to Peter Barna on three brands of insulating tape used at the Institute Plant. It reports that AMATEX tape contained raw asbestos fibers including dust, cites measurements of 0.03 to 1.9 fibers per cc at the Technical Center,…
-
Company document · Union Carbide documents · January 12, 1987
Industrial Hygiene Sampling Results for Asbestos Exposure During HAVEG Vessel Repair, Institute Plant Boilermaker Shop (1987)
Industrial hygiene report on air sampling for asbestos fibers taken November 13, 1986, while two boilermakers chipped HAVEG material to repair a vessel at the Institute Plant. It reports the eight-hour averages were below the permissible exposure…
-
Company document · Union Carbide documents · January 19, 1987
Industrial Hygiene Sampling Results for Asbestos Gasket Cutting in the Millwright and Motor Valve Shops, Institute Plant, to G. F. Morris (1987)
Industrial hygiene report from the Institute Plant on area air sampling for asbestos fibers at gasket-cutting stations in the Millwright Shop and Motor Valve Shop (Building 23), with samples taken on four dates in November 1986. The report says the…
-
Company document · Union Carbide documents · March 15, 1983
H. H. Frazier to R. G. Hull, Jr. on Personal Asbestos Exposure During Acetone Unit Demolition, Complex VI (1983)
Internal Union Carbide memo from Industrial Hygiene at the Institute Plant reporting three airborne asbestos samples taken during insulation demolition at the Acetone Unit. It gives results of 0.2, 0.5 and 0.8 fibers…
-
Company document · Union Carbide documents · March 15, 1983
H. H. Frazier to P. J. Morris on Personal Asbestos Exposure Monitoring of Two Insulator/Painters at Maintenance Complex VIII, Institute Plant (1983)
Internal Union Carbide memo reporting personal air monitoring of two insulator/painters removing protective covering from asbestos-insulated pipe valve at Maintenance Complex VIII on 2/3/83. It reports 15-minute results of 0.8…
-
Company document · Union Carbide documents · July 2, 1985
Industrial Hygiene Sampling Results for Asbestos in Gasket Cutting, Institute Plant, Building 325, with Attached Results Table (1985)
Industrial hygiene sampling report dated July 2, 1985 on asbestos monitoring during gasket cutting from Garlock and Durabla materials at Building 325, Institute Plant, sampled June 14, 1985. The comments state one personal and one area sample were…