Our medical research library holds 11 studies published in Journal of Applied Clinical Medical Physics (2008–2024). Each entry links to the study's record on PubMed and, where there is one, to the publisher's page and a free full text. 11 have an abstract, the authors' own summary as PubMed records it: open "Abstract" to read it.
You don't need the product names or old records. No fee unless we recover compensation for your family.
About the journal
- Publisher: Wiley on behalf of American Association of Physicists in Medicine
- Published: 2000 to the present, United States
- Language: English
- ISSN: 1526-9914 (electronic)
- Its record in the NLM Catalog
2020s
-
A radiotherapy community data-driven approach to determine which complexity metrics best predict the impact of atypical TPS beam modeling on clinical dose calculation accuracy. F.M.D. Brooks, M.C. Glenn, V. Hernandez, et al. 2024;25(5):e14318. PubMed · Publisher · Free full text
Abstract
Purpose: To quantify the impact of treatment planning system beam model parameters, based on the actual spread in radiotherapy community data, on clinical treatment plans and determine which complexity metrics best describe the impact beam modeling errors have on dose accuracy.
Methods: Ten beam modeling parameters for a Varian accelerator were modified in RayStation to match radiotherapy community data at the 2.5, 25, 50, 75, and 97.5 percentile levels. These modifications were evaluated on 25 patient cases, including prostate, non-small cell lung, H&N, brain, and mesothelioma, generating 1,000 plan perturbations. Differences in the mean planned dose to clinical target volumes (CTV) and organs at risk (OAR) were evaluated with respect to the planned dose using the reference (50th-percentile) parameter values. Correlation between CTV dose differences, and 18 different complexity metrics were evaluated using linear regression; R-squared values were used to determine the best metric.
Results: Perturbations to MLC offset and transmission parameters demonstrated the greatest changes in dose: up to 5.7% in CTVs and 16.7% for OARs. More complex clinical plans showed greater dose perturbation with atypical beam model parameters. The mean MLC Gap and Tongue & Groove index (TGi) complexity metrics best described the impact of TPS beam modeling variations on clinical dose delivery across all anatomical sites; similar, though not identical, trends between complexity and dose perturbation were observed among all sites.
Conclusion: Extreme values for MLC offset and MLC transmission beam modeling parameters were found to most substantially impact the dose distribution of clinical plans and careful attention should be given to these beam modeling parameters. The mean MLC Gap and TGi complexity metrics were best suited to identifying clinical plans most sensitive to beam modeling errors; this could help provide focus for clinical QA in identifying unacceptable plans.
© 2024 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.
-
Research on the correction method for radiotherapy verification plans based on displaced electronic portal imaging device. J. Guo, L. Zhou, H. Zeng. 2024;25(8):e14401. PubMed · Publisher · Free full text
Abstract
Background: It has been observed that under the single isocenter conditions, the potential shifts of the electronic portal imaging devices (EPID) may be introduced when executing portal dosimetry (PD) plans for bilateral breast cancer, pleural mesothelioma, and lymphoma. These shifts are relative to the calibration positions of EPID and result in significant discrepancies in the plan verification results.
Purpose: To explore methods including correction model and specific correction matrices to revise the data obtained from displaced EPID.
Methods: Two methods, the correction model and the specific correction matrices, were applied to correct the data. Five experiments were designed and conducted to build correction model and to validate the effectiveness of these two methods. Gamma passing rates were calculated and data profiles along X-axis and Y-axis were captured.
Results: The gamma passing rates for the EPID-displaced IMRT validation plans after applying correction model, along with the application of specific correction matrices to VMAT and IMRT validation plans, exhibit results that are comparable to the cases with non-displaced EPID. Except for the VMAT plans applied correction model which showed larger discrepancies (0.041 ± 0.028, 0.049 ± 0.030), the other three exhibit minimal differences in discrepancy values. In all profiles, the corrected data from displaced EPID exhibit a high level of agreement with data obtained from non-displaced EPID. Good consistency is observed in actual application of the correction model and the specific correction matrices between gamma passing rates of data corrected and those of non-displaced data.
Conclusions: The proposed methods involving correction model and specific correction matrices can correct the data collected from the displaced EPID, and the gamma passing rates of the corrected data show results that are comparable to some extent with those of non-displaced data. Particularly, the results corrected by specific correction matrices closely resemble the data from non-displaced EPID.
© 2024 The Author(s). Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.
2010s
-
Dual-input tracer kinetic modeling of dynamic contrast-enhanced MRI in thoracic malignancies. S.H. Lee, A. Rimner, J.O. Deasy, et al. 2019;20(11):169-188. PubMed · Publisher · Free full text
Abstract
Pulmonary perfusion with dynamic contrast-enhanced (DCE-) MRI is typically assessed using a single-input tracer kinetic model. Preliminary studies based on perfusion CT are indicating that dual-input perfusion modeling of lung tumors may be clinically valuable as lung tumors have a dual blood supply from the pulmonary and aortic system. This study aimed to investigate the feasibility of fitting dual-input tracer kinetic models to DCE-MRI datasets of thoracic malignancies, including malignant pleural mesothelioma (MPM) and nonsmall cell lung cancer (NSCLC), by comparing them to single-input (pulmonary or systemic arterial input) tracer kinetic models for the voxel-level analysis within the tumor with respect to goodness-of-fit statistics. Fifteen patients (five MPM, ten NSCLC) underwent DCE-MRI prior to radiotherapy. DCE-MRI data were analyzed using five different single- or dual-input tracer kinetic models: Tofts-Kety (TK), extended TK (ETK), two compartment exchange (2CX), adiabatic approximation to the tissue homogeneity (AATH) and distributed parameter (DP) models. The pulmonary blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), fractional interstitial volume (vI ), and volume transfer constant (KTrans ) were calculated for both single- and dual-input models. The pulmonary arterial flow fraction (γ), pulmonary arterial blood flow (BFPA ) and systemic arterial blood flow (BFA ) were additionally calculated for only dual-input models. The competing models were ranked and their Akaike weights were calculated for each voxel according to corrected Akaike information criterion (cAIC). The optimal model was chosen based on the lowest cAIC value. In both types of tumors, all five dual-input models yielded lower cAIC values than their corresponding single-input models. The 2CX model was the best-fitted model and most optimal in describing tracer kinetic behavior to assess microvascular properties in both MPM and NSCLC. The dual-input 2CX-model-derived BFA was the most significant parameter in differentiating adenocarcinoma from squamous cell carcinoma histology for NSCLC patients.
© 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
-
A pilot study of volumetric-modulated arc therapy for malignant pleural mesothelioma. L. Runxiao, C. Yankun, W. Lan. 2016;17(2):139-144. PubMed · Publisher · Free full text
Abstract
Malignant pleural mesothelioma (MPM) is an extremely difficult disease to treat. This pilot study investigates the feasibility of using volumetric-modulated arc therapy (VMAT) for malignant pleural mesothelioma (MPM), and compares VMAT to static field intensity-modulated radiotherapy (IMRT) for five patients. To identify the best treatment technique for MPM, in five patients, we made a representative comparative analysis of two kinds of techniques for radiation therapy planning: IMRT and VMAT. The plans were created for an Elekta Synergy linear accelerator with 6 MV photons using Oncentra version 4.3 treatment planning system. Dose prescription was 50 Gy to the average of the planning target volume (PTV). PTV coverage and homogeneity, dose of organs at risk, numbers of segments, MUs, and delivery time were evaluated for all techniques. VMAT allowed better homogeneous and conformity indices compared with IMRT (HI = 0.17 vs. 0.12, CI = 0.64 vs. 0.77, respectively, p < 0.05). VMAT plan had a significantly shorter delivery time (326 s) compared with in IMRT plans (510 s), (p < 0.05). In the dose verification, an average of 93.16% of the detector points passed the 3%/3 mmγ criterion for VMAT plans, while in IMRT plans the dose verification was 95.12%.(p > 0.05).
-
Geometric dose prediction model for hemithoracic intensity-modulated radiation therapy in mesothelioma patients with two intact lungs. L. Kuo, E.D. Yorke, V.A. Dumane, et al. 2016;17(3):371-379. PubMed · Publisher · Free full text
Abstract
The presence of two intact lungs makes it challenging to reach a tumoricidal dose with hemithoracic pleural intensity-modulated radiation therapy (IMRT) in patients with malignant pleural mesothelioma (MPM) who underwent pleurectomy/decortications or have unresectable disease. We developed an anatomy-based model to predict attainable prescription dose before starting optimization. Fifty-six clinically delivered IMRT plans were analyzed regarding correlation of prescription dose and individual and total lung volumes, planning target volume (PTV), ipsilateral normal lung volume and ratios: contralateral/ipsilateral lung (CIVR); contralateral lung/PTV (CPVR); ipsilateral lung /PTV (IPVR); ipsilateral normal lung /total lung (INTLVR); ipsilateral normal lung/PTV (INLPVR). Spearman's rank correlation and Fisher's exact test were used. Correlation between mean ipsilateral lung dose (MILD) and these volume ratios and between prescription dose and single lung mean doses were studied. The prediction models were validated in 23 subsequent MPM patients. CIVR showed the strongest correlation with dose (R=0.603,p<0.001) and accurately predicted prescription dose in the validation cases. INLPVR and MILD as well as MILD and prescription dose were significantly correlated (R=-0.784,p<0.001 and R=0.554,p<0.001, respectively) in the training and validation cases. Parameters obtainable directly from planning scan anatomy predict achievable prescription doses for hemithoracic IMRT treatment of MPM patients with two intact lungs. PACS number(s): 87.55.de, 87.55.dk.
-
On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors. D. McVicker, F.F. Yin, J.D. Adamson. 2016;17(1):34-48. PubMed · Publisher · Free full text
Abstract
We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical anisotropic algorithm within a commercial treatment planning system. Errors were implemented into the various components of the dose calculation algorithm including primary photons, secondary photons, electron contamination, and MLC parameters. For each error we evaluated the probability that it could be committed unknowingly during the dose algorithm commissioning stage, and the probability of it being identified during the verification stage. The clinical impact of each commissioning error was evaluated using representative IMRT plans including low and intermediate risk prostate, head and neck, mesothelioma, and scalp; the sensitivity of the TG-119 and IROC phantoms was evaluated by comparing dosimetric changes to the dose planes where film measurements occur and change in point doses where dosimeter measurements occur. No commissioning errors were found to have both a low probability of detection and high clinical severity. When errors do occur, the IROC credentialing and TG 119 commissioning criteria are generally effective at detecting them; however, for the IROC phantom, OAR point-dose measurements are the most sensitive despite being currently excluded from IROC analysis. Point-dose measurements with an absolute dose constraint were the most effective at detecting errors, while film analysis using a gamma comparison and the IROC film distance to agreement criteria were less effective at detecting the specific commissioning errors implemented here.
-
Evaluation of 4D CT acquisition methods designed to reduce artifacts. S.J. Castillo, R. Castillo, E. Castillo, et al. 2015;16(2):4949. PubMed · Publisher · Free full text
Abstract
Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled to undergo radiation therapy received standard clinical 4D CT scans followed by each of the alternative 4D CT acquisitions: 1) data oversampling, 2) beam gating with breathing irregularities, and 3) rescanning the clinical acquisition acquired during irregular breathing. Relative values of a validated correlation-based artifact metric (CM) determined the best acquisition method per patient. Each 4D CT was processed by an extended phase sorting approach that optimizes the quantitative artifact metric (CM sorting). The clinical acquisitions were also postprocessed by phase sorting for artifact comparison of our current clinical implementation with the experimental methods. The oversampling acquisition achieved the lowest artifact presence among all acquisitions, achieving a 27% reduction from the current clinical 4D CT implementation (95% confidence interval = 34-20). The rescan method presented a significantly higher artifact presence from the clinical acquisition (37%; p < 0.002), the gating acquisition (26%; p < 0.005), and the oversampling acquisition (31%; p < 0.001), while the data lacked evidence of a significant difference between the clinical, gating, and oversampling methods. The oversampling acquisition reduced artifact presence from the current clinical 4D CT implementation to the largest degree and provided the simplest and most reproducible implementation. The rescan acquisition increased artifact presence significantly, compared to all acquisitions, and suffered from combination of data from independent scans over which large internal anatomic shifts occurred.
-
A six-year review of more than 13,000 patient-specific IMRT QA results from 13 different treatment sites. K.B. Pulliam, D. Followill, L. Court, et al. 2014;15(5):4935. Review PubMed · Publisher · Free full text
Abstract
Due to a lack of information regarding the current clinical experience of IMRT QA for a large and varied plan population, we reviewed our patient-specific IMRT quality assurance (QA) results for 13,003 treatment plans from 13 distinct treatment sites from a six-year period. QA records were reviewed for dose difference (single point with ion chamber measurement; ± 3% agreement criteria) and percentage of pixels passing relative dose gamma analysis (film measurement; 90% passing 5%(global)/3 mm agreement criteria) from 2005 through 2011. Plan records were analyzed for trends with measurement date and treatment site. Plans failing to meet QA tolerance criteria were evaluated for follow-up clinical action (i.e., if repeat measurements were performed). The mean difference (± SD) between ion chamber point measurements and calculated doses was -0.29% ± 1.64% (calculated values being slightly higher) and, regarding planar dose evaluations, the mean percentage of pixels passing the gamma criteria of 5%(global)/3 mm was 97.7% (lower 95th percentile: 92.2%). 97.7% and 99.3% of plans passed the point dose and planar dose verification, respectively. We observed statistically significant differences (p< 0.05) in both point dose and planar dose verification measurements as a function of treatment site (particularly for stereotactic spine and mesothelioma sites) and measurement date (average agreement improved with time). However, despite improved dosimetric agreement, the percentage of failing plans has remained nearly constant at 2.3%.
-
Intensity-modulated radiotherapy and volumetric-modulated arc therapy for malignant pleural mesothelioma after extrapleural pleuropneumonectomy. J. Krayenbuehl, O. Riesterer, S. Graydon, et al. 2013;14(4):4130. PubMed · Publisher · Free full text
Abstract
Radiotherapy reduces the local relapse rate after pleuropneumonectomy of malignant pleural mesothelioma (MPM). The optimal treatment technique with photons remains undefined. Comparative planning for intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) was performed. Six MPM patients with significant postoperative intrathoracic air cavities were planned with IMRT and VMAT. A dose comparison for the targets and organ at risks (OAR) was performed. Robustness was assessed in respect to the variation of target dose with change in volume of air cavities. VMAT reduced the dose to the contralateral lung by reducing the volume covered by 13 Gy and 20 Gy by a factor 1.8 and 2.8, in respect to IMRT (p = 0.02). Dose distribution with VMAT was the most stable technique in regard to postsurgical air cavity variation. For IMRT, V90, V95, and the minimal target dose decreased by 40%, 64%, and 12% compared to 29%, 47%, and 7% with VMAT when air cavity decreased. Two arcs compared to one arc decreased the dose to all the organs at risk (OAR) while leaving PTV dose coverage unchanged. Increasing the number of arcs from two to three did not reduce the dose to the OAR further, but increased the beam-on time by 50%. Using partial arcs decreased the beam-on time by 43%. VMAT allows a lower lung dose and is less affected by the air cavity variation than IMRT. The best VMAT plans were obtained with two partial arcs. VMAT seems currently the most suitable technique for the treatment of MPM patients when air cavities are remaining and no adaptive radiotherapy is performed.
2000s
-
Evaluation of the dose calculation accuracy in intensity-modulated radiation therapy for mesothelioma, focusing on low doses to the contralateral lung. L.E. Court, D. Ching, D. Schofield, et al. 2009;10(2):34-42. PubMed · Publisher · Free full text
Abstract
This study compares Monte Carlo (MC) with conventional treatment planning system (TPS) calculations. The EGS4nrc MC code, BEAMnrc, was commissioned to simulate a Varian 21Ex Linac. The accuracy of the simulations, including points blocked by the jaws, was evaluated by comparing MC with ion chamber and MOSFET measurements. Eight mesothelioma IMRT cases were planned using Eclipse (pencil beam and superposition convolution algorithms). Dose distributions were recalculated using BEAMnrc/DOSxyz, and compared with TPS. MC agreed with experimental results for IMRT fields within 3% (96% of points). For regions blocked by the jaws, average agreement between MC and experiment was better than 5% up to 20 cm from isocenter. The pencil beam algorithm underestimated lung MLD, V20, and V5, compared with MC, by a mean (range) of 16% (11-22%), 9.0% (2.4-30.1%), and 11.8% (2-30%), respectively. The superposition convolution algorithm gave better agreement of 8.5% (0-17%), 4% (0-12%) and 0% (-6-6%). Mean dose to the targets was better than +/- 5% in all cases. In conclusion, there is excellent correlation between TPS and MC calculations for the target doses. The pencil beam algorithm and superposition convolution algorithms both underestimate lung dose parameters, but the superposition convolution dose offers improvements in dose calculation accuracy for these patients.
-
Compensator-based intensity-modulated radiation therapy for malignant pleural mesothelioma post extrapleural pneumonectomy. K. Javedan, C.W. Stevens, K.M. Forster. 2008;9(4):98-109. PubMed · Publisher · Free full text
Abstract
The present work investigated the potential of compensator-based intensity-modulated radiation therapy (CB-IMRT) as an alternative to multileaf collimator (MLC)-based intensity-modulated radiation therapy (IMRT) to treat malignant pleural mesothelioma (MPM) post extrapleural pneumonectomy. Treatment plans for 4 right-sided and 1 left-sided MPM post-surgery cases were generated using a commercial treatment planning system, XIO/CMS (Computerized Medical Systems, St. Louis, MO). We used a 7-gantry-angle arrangement with 6 MV beams to generate these plans. The maximum required field size was 30 x 40 cm. We evaluated IMRT plans with brass compensators (.Decimal, Sanford, FL) by examining isodose distributions, dose-volume histograms, metrics to quantify conformal plan quality, and homogeneity. Quality assurance was performed for one of the compensator plans. Conformal dose distributions were achieved with CB-IMRT for all 5 cases, the average planning target volume (PTV) coverage being 95.1% of the PTV volume receiving the full prescription dose. The average lung V20 (volume of lung receiving 20 Gy) was 1.8%, the mean lung dose was 6.7 Gy, and the average contralateral kidney V15 was 0.6%. The average liver dose V30 was 34.0% for the right-sided cases and 10% for the left-sided case. The average monitor units (MUs) per fraction were 980 MUs for the 45-Gy prescriptions (mean: 50 Gy) and 1083 MUs for the 50-Gy prescriptions (mean: 54 Gy). Post surgery, CB-IMRT for MPM is a feasible IMRT technique for treatment with a single isocenter. Compensator plans achieved dose objectives and were safely delivered on a Siemens Oncor machine (Siemens Medical Solutions, Malvern, PA). These plans showed acceptably conformal dose distributions as confirmed by multiple measurement techniques. Not all linear accelerators can deliver large-field MLC-based IMRT, but most can deliver a maximum conformal field of 40 x 40 cm. It is possible and reasonable to deliver IMRT with compensators for fields this size with most conventional linear accelerators.
Browse every journal in the library or the library by type of article, or return to medical research.
Cite this page
“Journal of Applied Clinical Medical Physics.” AsbestosClaims.Law Library. https://asbestosclaims.law/library/research/journals/journal-of-applied-clinical-medical-physics.
ACL Doc numbers and their short links never change. See how to cite the Library.
Talk with an asbestos lawyer
Start with what you remember, and we'll take it from there.
This page is provided for general informational purposes and does not constitute legal advice. Every asbestos case turns on its own facts, exposure history, diagnosis, deadlines, available evidence, and applicable law. Reviewing this page does not create an attorney-client relationship. For advice about your specific situation, call 833-4-ASBESTOS for a free case review.