You don't need the product names or old records. No fee unless we recover compensation for your family.
Internal memo reporting air sampling of construction insulators removing asbestos-containing insulation from a 3-inch steam line at the Institute, West Virginia, plant on March 17 and 19, 1979. It reported fiber concentrations of 0.7 to 3.4 fibers/cc without wetting and 0.2 and 0.4 fibers/cc with wetting, said exposures were below OSHA limits, and recommended wet methods and posted barricade tape and warning signs.
- Author
- W. F. Blythe, Jr. (Technical Center Industrial Hygiene Group); G. F. Hurley (approver)
- Published by
- Union Carbide Corporation, Chemicals and Plastics, Technical Center IH/EP
- Series
- Union Carbide documents, UC-3230
- Date
- March 29, 1979
- Number
- Bates UCC 016668 to UCC 016669
- Library no.
- ACL Doc 18041 · asbestosclaims.law/library/18041
- Rights
- A document from asbestos litigation, published for research and historical study.
Read or download
Read online Download the PDF Document UC-3230 · 2 pages · 98 KB
People and organizations
From W. F. Blythe, Jr. (Technical Center Industrial Hygiene Group); G. F. Hurley (approver) to Mr. D. L. Johnson; Mr. E. C. Shipley; Mr. E. J. Tawney; Mr. L. R. Noble (copy); Mr. H. L. Robinson (copy).
- William F. Blythe, Jr. (author)
- George F. Hurley (author)
- D. L. Johnson (recipient)
- E. C. Shipley (recipient)
- E. J. Tawney (recipient)
- L. R. Noble (copied)
- H. L. Robinson (copied)
- Technical Center IH/EP (its organization)
- Union Carbide Corporation (its organization)
- OSHA (named)
- Technical Center Industrial Hygiene Group (named)
Related pages
Pages on our site about what this document covers: Air Sampling · Asbestos Exposure in Insulators and Insulation Workers · OSHA · Permissible Exposure Limit (PEL) · West Virginia Asbestos Exposure Sites: Worksites, Industries, and Trust Coverage.
About this copy
This is document UC-3230 of the Union Carbide documents, documents produced and used as evidence in asbestos lawsuits against Union Carbide, 2 pages. Production numbers UCC 016668 to UCC 016669.
Cite this document
“W. F. Blythe, Jr. to D. L. Johnson, E. C. Shipley and E. J. Tawney on Asbestos Monitoring of Insulators at Institute.” March 29, 1979. Union Carbide documents, UC-3230, Bates UCC 016668 to UCC 016669. Union Carbide Corporation, Chemicals and Plastics, Technical Center IH/EP. AsbestosClaims.Law Library, ACL Doc 18041. https://asbestosclaims.law/library/18041.
ACL Doc numbers and their short links never change. See how to cite the Library.
Talk with an asbestos lawyer
Start with what you remember, and we'll take it from there.
This page is provided for general informational purposes and does not constitute legal advice. Every asbestos case turns on its own facts, exposure history, diagnosis, deadlines, available evidence, and applicable law. Reviewing this page does not create an attorney-client relationship. For advice about your specific situation, call 833-4-ASBESTOS for a free case review.